(HB1372)AMENDMENTS PROPOSED BY THE SENATE
1. Page 1, engrossed, line 20, after (ii)
insert
marked with an American Society of Mechanical Engineers (ASME) Stamp, (ii)
2. Page 1, engrossed, line 21, after (iii)
strike
(ii)
insert
(iii)
3. Page 1, engrossed, line 21, after seal.
insert
The requirement of subdivision (i) shall be waived for model boilers upon the passage of an accumulation test.
4. Page 1, engrossed, line 28, after test
insert
. The pressure shall be
5. Page 1, engrossed, line 28, after one and
strike
one-half
insert
one-quarter
6. Page 1, engrossed, line 29, after pressure,
strike
remainder of line 29 and line 30 through frequently
insert
as determined by the inspection certificate and
7. Page 1, engrossed, line 31, after is not
strike
certified
insert
registered
8. Page 1, engrossed, line 32, after tested to
strike
twice
insert
one and one-half times
9. Page 1, engrossed, line 32, after pressure
insert
for antique boilers and twice the maximum allowable working pressure for model boilers
10. Page 1, engrossed, line 33, after (i)
insert
for lap seam and non-standard welded boilers only,
11. Page 1, engrossed, line 35, after (iii)
insert
for antique boilers with lap seam construction,
12. Page 1, engrossed, after line 37
insert
The requirements of this subsection for antique boilers only testing to one and one-half times the maximum allowable working pressure or full radiographic or ultrasonic examination may be waived after the initial inspection if the inspector finds that the general standards of subsection B are met and the safety valve or valves are set at the maximum allowable working pressure determined by the following: calculations from the ultrasonic results of 100 pounds per square inch, whichever is lower. If a variance is requested for butt strap antique boilers, the commissioner shall not deny such variance request without a given, valid reason.
13. Page 1, engrossed, line 38, after for
insert
model boilers only for